5-11
List of Log Messages
Appendix
A230 Video input warning detected [warning]
A270 Upload image buffer overflowed [warning]
A271 E-mail communication buffer overflowed [warning]
A272 Upload communication buffer overflowed [warning]
A321 Video control command failed [err]
A420 Video input initialization failed [crit]
Description stream buffer overflowed (A230)
Meaning
The image buffer for stream recording overflowed and the
application began discarding images.
Description %1 images are lost due to upload buffer overflow (A270)
%1 Number of discarded upload images
Meaning Upload images overflowed from the image buffer.
Countermeasure
Make adjustments to reduce the number of event occurrences. Also
adjust the upload quality, image size and frame rate.
Description mail queue is full (A271)
Meaning E-mails overflowed from the communication buffer.
Countermeasure
Make adjustments to reduce the number of event occurrences. Also
adjust the upload quality and resolution.
Description ftp/http queue is full (A272)
Meaning Upload data overflowed from the communication buffer.
Countermeasure
Make adjustments to reduce the number of event occurrences. Also
adjust the upload quality, image size and frame rate.
Description video%1 command error - <Cause of error> (A321)
%1 Video input number
Meaning
Issuance of a command to the video input system failed. If this error
occurs frequently, an A42x error will occur.
Description video%1 initialization failure - <Cause of error> (A420)
%1 Video input number
Meaning
The video input function was stopped because the video input
system could not be initialized.